Programming
3
All relay outputs are active high. One side of all of the relay contacts is tied to a common point
called Output Common (pin 2). When using the in24 V (pin 1) as a source for these out-
puts, you must connect Output Common (pin 2) and +24 V (pin 1). The outputs will then be refer-
enced to GND (pin 11). For hardware pin location please see page 19.
Note:
When active, the Fieldbus inputs have priority. Refer to help page for Advanced / Fieldbus.
outputs.txtE
NOK
Active if Torque / Angle / Yield are outside limits or some
other error has occurred
Torque Low
Active if Peak Torque < Torque Low Limit
Torque High
Active of Peak Torque > Torque High Limit
Angle Low
Active if Angle < Angle Low Limit
Angle High
Active of Angle > Angle High Limit
Torque OK
Active if Peak Torque is within limits
Angle OK
Active if Angle is within limits
Tool Running
Active when the tool is running
Cycle Complete
Active when a rundown has ended in the last stage
Linking Complete
Active when rundowns of all positions of the selected batch
group are complete
Linking OK
Active if all positions of Linking were OK
Linking NOK
Active if one or more positions of Linking were NOK
Confirm App. Sel 0
Confirm application Selects 0-7 are used to indicate the
currently selected applications 1-255 using a binary count
of 0-254 where Appl. Select 0 is the least significant bit
Confirm App. Sel 1
Confirm App. Sel 2
Confirm App. Sel 3
Confirm App. Sel 4
Confirm App. Sel 5
Confirm App. Sel 6
Confirm App. Sel 7
Sync Output
If enabled from Advanced / System Settings it is active at
the end of each stage to allow for synchronization with
other controllers
Tool In Reverse
Indicates that a tool reverse input or actuator is set
Socket Tray Enable
Pass-through of Socket Tray Enable input signal
Socket Tray Sel 0
Pass-through of Socket Tray select 0-2 input signals
Socket Tray Sel 1
Socket Tray Sel 2
Fault (Active Low)
Indicates the servo module has detected an error (trans-
ducer, resolver etc)