en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
63
Programming
3
The following table details the transmission data for Standard2:
Start
End
Length or Value
Description
1
1
42 hex
B
2
3
2 Digit ASCII
Tool Number
4
6
3 Digit ASCII
Parameter Set
7
18
12 Char ASCII
Date and Time (YYMMDDHHMMSS)
19
25
7 Digit ASCII
Peak Torque
26
32
7 Digit ASCII
Low Torque Limit
33
39
7 Digit ASCII
High Torque Limit
40
40
1 Char ASCII Status
Torque Status Flag
L = low
A = accept
H = high
41
47
7 Digit ASCII
Final Angle
48
54
7 Digit ASCII
Low Angle Limit
55
61
7 Digit ASCII
High Angle Limit
62
62
1 Char ASCII Status
Angle Status Flag
L = low
A = accept
H = high
63
63
1 Char ASCII Status
Overall Status Flag
A = accept
R = reject
64
65
2 Digit ASCII
Link/Position
(Only for Linking)
66
67
2 Digit ASCII
Number of linked positions
(Only for Linking)
68
68
0D hex
CR (carriage return)
69
69
0A hex
LF (line feed)
If Part ID is ENABLED, then a 25 character ASCII part ID is transmitted prior to CR/LF.
TM-COM via COM1
When this feature is enabled the COM1 serial port is reserved solely to listen for an incoming
TM-COM connection. The COM2 port remains available for other functions; however, on the
TME-200 product COM2 is used to support the fieldbus interface and is not available if fieldbus is
activated.
Activating this feature requires restarting the controller. Once activated, this feature allows
another PC running TM-COM to connect via the COM1 serial port so that parameters may be
saved/loaded, etc.