54
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
Reject Release
Max Number of Rejects
Allows the user to enter the maximum number of rejects that
will be permitted before a release signal is required. If 0 is
entered, the function is disabled.
Release Method
Release on Backoff
Allows the user to release the tool by running the tool in
reverse.
Release Input Toggle
Allows the user to set a low-high-low pulse of the Reject
Release input as a release signal
Others
Torque Units
Allows the user to select which units the controller uses for
presenting torque. Available choices: Nm, FtLbs, InLbs,
KgCm, KgM and dNm. When the units are changed, all new
torque values are immediately changed to the new units and
all rundown data is cleared.
Tool Sync/Disable Linking
Allows the user to enable Tool Synchronization and disable
the linking function.
NOK if Start Switch
Release
Causes NOK status after any rundown with Early Trigger
Release (ETR). ETR is any case in which the rundown did
not end progamatically, i.e. if the tool did not reach Turn Off
or High Limit torque or angle, or reach Max Fastening time.
In this case an NOK result is generated and the yellow LEDs
on the TME and tool will be illuminated.
Archive only if Torque >
Trigger
Allows the user to specify that only rundown cycles where
the torque is greater than the trigger torque of the last tight-
ening stage will be saved in Chrono History.
External Application Select
Allows the user to enable the requirement for an external sig-
nal into the inputs Appl. Select 0-7 (Appl. Select 0-2 with a
socket tray) for selecting the application. In the absence of a
signal, the TME controller defaults to application 1.
External Tool Enable
Allows the user to enable the requirement for an external sig-
nal Input before the rundown cycle can begin.
Latched Remote Start
Allows the user to enable the requirement for an external
pulse signal input to start the rundown cycle. If unchecked
the remote start signal must be maintained for the tool to
continue running.
Blinking Lights in Reverse
(TME only) Allows the user to select the option of blinking
lights on TME controller and tool when the tool is in reverse.
If the box is unchecked, there is no visible indication that the
tool is in reverse.
sysset.txtE