Programming
3
Rundown Indicator
At the bottom left of the display is the rundown indicator. The final torque and angle values are
displayed on either a green (OK) background or red (NOK) background.
Parameters
At the bottom of the display is a summary of the parameter settings for the rundown.
The Save softkey <F2> lets you print a hardcopy.
Note:
The TMEI does not provide access to the Oscilloscope screen.
oscope.txtE
3.7
Communication
3.7.1
Communications / Data Transmission
c0
04
04
e
n.
b
mp
Fig. 3-26: Data Transmission
commdata.txtS
From the Data Transmission Screen the Serial and Ethernet connections can be configured.
Serial
Protocol
None, Standard, Standard2, PFCS, CT01 3964R,
Appolo 3.1, FEP
Port
COM 1, COM 2
Baud Rate
2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200
Data Bits
4, 5, 6, 7, 8
Parity
None, Odd, Even, Mark, Space
Stop Bits
1, 1.5, 2
Flow Control
None, Hardware, Xon/Xoff