Programming
3
3.4.7
Advanced Application Builder / System Settings
c0
03
13
en
.bm
p
Fig. 3-19: System Settings
sysset.txtS
From the System Settings Screen the user can configure parameters pertaining to the system.
General
Allows the user to assign an identifying name and number to the TME controller. This information
will be used when sending and printing data.
Station Name
(10 characters - alphanumeric)
Station Number
(10 characters - alphanumeric)
Work Cell Name
(25 characters - alphanumeric)
Work Cell Number
(3 characters - alphanumeric)
File Name Prefix
(15 characters - alphanumeric)
This string is appended to the front of default file names so
that multiple controller files can be saved to the same disk
media.
Same for both tools
(2-Channel only) When this box is checked, the most
recently entered Station Name and Station Number are auto-
matically synchronized and used for both tools. When not
checked, the Station Name and Station Number may be pro-
grammed differently for each tool.
The use of this check box also affects the serial communica-
tion protocols Standard, Standard2, and 3964R. If "Same for
both tools" is not checked, then the 2-digit ASCII tool number
transmitted is taken from the Station Number field. If "Same
for both tools" is checked, then the 2-digit ASCII tool number
transmitted is hard-coded to be "01" or "02" depending on
which tool the results data is from.