en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
49
Programming
3
Signal Descriptions
Inputs
If DeviceNet configuration is selected, the input packet is 4 Words long (8 bytes) including Part ID
Number (4 bytes) if enabled, or 2 words long (4 bytes) if Part ID is not enabled.
If Profibus configuration is selected, the input packet is 4 words long (8 bytes).
WORD 0
BYTE 0
BIT 0-3:
Spare
BIT 4-6:
Application/Link. Select Code 1-8(Bit 4=LSB)
BIT 7:
Reset Linking
BYTE 1:
BIT 0:
Remote Tool Start
BIT1:
Remote Tool Reverse
BIT 2:
Tool Ready (Flashing Yellow Light)
BIT 3:
Tool Enable
BIT 4:
Socket Tray Lamps Enable
BIT 5:
Socket Tray Lamps Appl. Sel. 0
BIT 6:
Socket Tray Lamps Appl. Sel. 1
BIT 7:
Socket Tray Lamps Appl. Sel. 2
WORD 1
BYTE 0
BIT 0-4:
Application/Link. Select Code 9-255 (Bit 0=LSB)
BIT 5-7:
Spare
BYTE 1
ALL:
Spare
WORD 2
BYTE 0
ALL:
Part ID
BYTE 1
ALL:
Part ID
WORD 3
BYTE 0
ALL:
Part ID
BYTE 1
ALL:
Part ID
Example of Part ID (BCD - HEX Format)
WORD 3
BYTE 1
00000000 - 00
BYTE 0
00000010 - 02
WORD 2
BYTE 1
11111111 - FF
BYTE 0
00000001 - 01
The HEX-Format (0002FF01) will be displayed on the Run Screen, Chrono History, and Printout.