66
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
Barcode Serial Interface
Defines the serial port used to interface to the barcode reader.
Note:
The default port for the serial barcode interface is COM2.
Port
COM1, COM2
Baud Rate
2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200
Data Bits
4, 5, 6, 7, 8
Parity
None, Odd, Even, Mark, Space
Stop Bits
1, 1.5, 2
Flow Control
None, Hardware, Xon/Xoff
Termination
Defines what (if any) characters the barcode reader appends
to the barcode when transmitting to the serial interface
(None, CR/LF, LF, CR)
Configure Data
The Part ID: Configure Data screen is entered by pressing <F3> “Configure Data” from the Part
ID edit screen. Up to 12 position/value pairs may be entered, along with corresponding functions.
When a new Part ID is received by the controller, the table of entries is scanned. An entry which
matches a Part ID character “Value” in the corresponding “Position” causes the associated
"Function" to be engaged.
The entries are displayed in a table at the top of the screen. The “Position”, “Value”, “Function”
and “App/Group” edit boxes are at the bottom of the screen. Pressing the <F1> “Add” key causes
the current values in the edit boxes to be added to the table. All values are validated prior to
Data Function
Allows the tool functionality to be automatically controlled based on the
Part ID. See “Configure Data” below.
None
The Part ID characters have no control over the tool
functionality. The <F3> “Configure Data” soft key on the
Part ID configuration screen is disabled. NOTE: setting
this option to “None” does NOT cause Configure Data
table entries to be lost.
Configure Data
The Position/Value pairs on the Configure Data screen
may be used to control the tool functionality. When
selected, the <F3> “Configure Data” key is enabled.
From the Configure Data screen, the user may enter
Position/Character pairs with associated functions to
control the tool based on the part ID.
Batch interrupt.
Defines the way a new scanned ID number should be handled during
batching. Activated when "Enable" is set to "Enable Interlocked".
Reset
Running batching will be interrupted and the scanned
PartID number will be used for the next batching. NOK
will be reported for any batch operation that is termi-
nated prior to completion. NOK will be held for 1.5 s
after the batch is aborted, and then the new batch will
start.
Ask
The user will be asked how to proceed with new
scanned number. (e.g. finish current batching or inter-
rupt batching and start with new one.)