38
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
3.3.5
Standard Application Builder / Advanced Parameters
c00
283
en
.bm
p
Fig. 3-10: Advanced Parameters
advparam.txtS
The user can enter the Advanced Parameters using the Advanced <F3> soft key from the
Parameter screen. These parameters are identical regardless of the selected Fastening
Sequence.
The Next Stage <F2> key will increment to the next stage until it reaches the last stage with a
selected Sequence. It will then rollover to the first stage. In order to add a stage without a
selected Sequence the user must highlight the stage field and enter a number 1-6.
Timers
Start delay time [mS]
time delay before the stage will start
Start spike time [mS]
time delay for the control system to start measuring torque after the stage
starts
Max. Fastening time [mS]
max time for the tool to run during the stage.
End delay time [mS]
time delay from tool turn off until shut-off of measured value recording.
Other
Torque Filter Factor
used for torque averaging