Essential Configuration - Quick Reference
This section is a quick reference list of the essential configuration steps that must be
performed during the execution of the Setup Wizard and/or after the Setup Wizard has
been run to ensure proper functionality of the units. A full description of the features
described below begins with the
Essential Configuration – Switch Module
section later in
this document.
1. Set the Region Code. This is the Country the unit will be operating in. See the Switch
Module – Essential Setup Wizard Configuration and Remote Module – Essential
Setup Wizard configuration sections for full details.
Only configurable using Setup Wizard.
Path:
Gateway (and Remote)->Utilities->Setup_Wizard
►
Refer to page
xx and yy
for full details.
2. Set the PBX Type. This is the phone protocol the unit will be using. See the Switch
Module – Essential Setup Wizard Configuration and Remote Module – Essential
Setup Wizard configuration sections for full details.
Only configurable using Setup Wizard.
Path:
Gateway (and Remote)->Utilities->Setup_Wizard
►
Refer to page
xx and yy
for full details.
3. Set the Telco type, dialup or leased line operation. Configure the Modem Settings for
communication between the Switch and Remote Module. See the Switch Module
Essential Connect Parameters - Modem Settings
and the Remote Module Essential
Connect Parameters sections for full details.
Path:
Gateway(and Remote)->Configuration->Connect->Modem_Settings
TMI Path:
(Remote Only)->Set Config->Modem Menu->Leased Line
►
Refer to page
39
and yy for full details.
4. Set the Dial Numbers for the Remote Module (If Leased Line is disabled). These are
the phone numbers of the analog telephone lines connected to the Switch and
Remote Modules. See the Remote Module
Essential Connect Parameters – Dial
Numbers
for full details.
Path:
Remote->Configuration->Connect->Dial_Numbers
TMI Path:
(Remote Only)->Set Config->Connect Menu->Office Number
►
Refer to page
42
for full details.
5. Set the User ID on Remote Side. It is recommended but not required to set the
Remote User ID, if not configured you will be prompted to enter User ID on each
connect to Switch Module. The default User ID is 1 on Switch side. See the Remote
Module
Advanced Port Setup
for full details.
Path:
Remote->Configuration->Port->User_ID
TMI Path:
(Remote Only)->Set Config->Connect Menu->User ID
►
Refer to page
xx
for full details.