![Citel EXTender 1100 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/citel/extender-1100/extender-1100_system-administrator-manual_2609638031.webp)
EXTender 1100A Switch and Remote Module System Administrator’s
Guide
31
5 C
ONFIGURING THE
S
WITCH
M
ODULE
AND
R
EMOTE
M
ODULE
The Switch Module and Remote Module must be installed properly and the analog lines
on both devices must be operational before continuing.
Initial configuration
Do NOT connect the Switch Module to the PBX or connect the digital telephone to
the Remote Module until the Setup Wizard has been run. An improperly configured
Switch Module can cause damage to the PBX line card and an improperly
configured Remote Module can cause damage to the digital telephone set.
!
The Setup Wizard
The Switch Module and Remote Module are programmed at the factory with “default”
settings including no PBX protocol and providing basic parameters to accommodate many
network environments. It will be necessary to select the desired PBX type and change
these settings for the specific network, user or corporate requirements.
The Setup Wizard is presented first with all new installations. The wizard will prompt the
Administrator to enter required information necessary for basic configuration of the Switch
Module and Remote Module. Simply follow the prompts to perform a basic configuration.
Refer to this manual for a full description of the features presented when running the
Setup Wizard.
If it becomes necessary to run the Setup Wizard at any time after the initial installation it
can be accessed here:
Path:
Gateway (and Remote) ->Utilities->Setup Wizard
Changing Passwords
Administrator Password
The administrator password provides access to the MC (Management Console) and MB
(Management Browser). It is recommended to set an administrator password for the
Switch Module and Remote Module because the units are shipped with no default
password. Always keep passwords in a secure location.
Although setting the administrator password is described later in this document as part of
the configuration steps it can be changed at any time after the initial installation here:
Path:
Gateway (and Remote) ->Utilities->System->Set Password
If the unit’s password is lost or forgotten please contact a customer support representative
at 1-877-248-3587 or
for details on how to reset the password. Port
passwords are not affected.
Document Number: M-1100A-MUC
Version: Rev AG