Chapter 7 Basic SCE 1000 Platform Operations
Starting the SCE 1000 Platform
Cisco SCE 1000 2xGBE Installation and Configuration Guide
OL-7821-05
7-3
If the system does not complete each of the steps in the startup procedure, proceed to
Troubleshooting
(on page
8-1
) for troubleshooting recommendations and procedures.
Final Tests
The procedures for performing the final tests to verify that the
SCE 1000
is functioning properly
are explained in the following sections:
•
Verifying Operational Status
(on page
7-3
)
•
Viewing the User Log Counters
(on page
7-3
)
Verifying Operational Status
After all the ports are connected, verify that the
SCE 1000
is not in a Warning state.
To verify that the
SCE 1000
is not in a warning state, complete the following steps:
Step 1
On the
SCE 1000
Front panel, examine that the Status LED is flashing green.
Step 2
To display the operation status of the system, at the
SCE 1000
#
prompt, type
show system
operation-status
and press
Enter
.
A message displaying the operation status of the system appears. If the system is operating in
order, the following message appears:
System Operation status is Operational.
E
XAMPLE
:
The following example displays a sample output where the LEDs appear red/orange:
SCE 1000
#
show system operation-status
System Operation status is Operational
Viewing the User Log Counters
View the user log for errors that occurred during the installation process.
To display the user log device counters, complete the following steps:
At the
SCE 1000
#
prompt, type
show logger device User-File-Log counters
and
press
Enter
.
E
XAMPLE
:
The following example shows the current User-File-Log device counters.
SCE 1000
#
show logger device user-file-log counters
Logger device User-File-Log counters:
Total info messages: 1