54
AFQm
Instruction Manual
Table 20 (Cont�) : Alarm messages�
Alarm messages
High temp Inductor
Description
The temperature of the inductors is very high.
Corrective
action
Check that the fans are working. Clean or replace the fans if necessary. If it continues,
contact
the
TAS�
Resonance
Description
Detection of a potential resonance with a load
Corrective
action
The resonance detection function can be activated erroneously in installations with a very high
voltage THD. Contact the
TAS
.
Initial Conditions
Description
The start-up conditions have not been met 10 times during the past 5 minutes.
Corrective
action
Check the configuration and the ambient temperature. Check the quality of the power supply
voltage. If it persists, contact the
TAS�
Internal communications
Description
Failure in internal communications.
Corrective
action
Restart. Contact the
TAS
.
Hardware failure
Description
The self-diagnostic system has detected a fault.
Corrective
action
Contact the
TAS
.
Exxx or Cxxx
Description
Internal error.
Corrective
action
Contact the
TAS
.
6.14.- WARNINGS
Note:
This screen is not visible on the
“slave”
devices.
When the device generates a warning, it will continue to operate, but the
symbol will be
displayed on the main screen.
On pressing the
key; if there are active warnings, the screen shown in
Figure 54
, will be
displayed and the user will be asked for confirmation to continue with the filter start-up process.
Figure 54:
Confirm screen.
Содержание AFQm Series
Страница 1: ...INSTRUCTION MANUAL Active Parallel Multi Function Filter AFQm M217B01 03 19B...
Страница 2: ...2 AFQm Instruction Manual...
Страница 103: ...103 Instruction Manual AFQm 608 812 1755 665 465 1890 Figure 98 Dimensions Cabinet type AFQm...
Страница 105: ...105 Instruction Manual AFQm 14 CE CERTIFICATE...
Страница 106: ...106 AFQm Instruction Manual...
Страница 107: ...107 Instruction Manual AFQm...