USER GUIDE
Visit us online: shunyata.com
Страница 1: ...USER GUIDE Visit us online shunyata com ...
Страница 2: ...d on the side of the box and on the unit before applying power WATER This unit is NOT water proof Do NOT submerge unit in water or any other fluid Do NOT operate unit in an environment of water condensation Do NOT operate unit with standing water on the floor INPUT POWER REQUIREMENTS This unit requires a properly installed AC Mains power connection Ensure that the AC polarity is correct and that a...
Страница 3: ...in complex home entertainment systems Home entertainment systems can be very complex involving many components located in multiple locations These systems may use several dedicated power lines making it almost impossible to effectively reduce power line noise with a single box power conditioner solution Shunyata Research solves this problem by intercepting noise at multiple locations in the entert...
Страница 4: ...ly reduces the daisy chained wires terminal strips and terminal connectors found within common power conditioners The power outlets electrical terminals and main electrical buss are all unified into a single OFC copper buss that dramatically improves DTCD CGS CHASSIS GROUNDING SYSTEM The TRITON v2 includes the exclusive Chassis Grounding System CGS This provides a central grounding point for all e...
Страница 5: ...lusive vibration absorbing AC outlet gaskets and chassis dampeners that measurably reduce resonant vibration levels CONNECTIONS AND POWER UP THE ELECTROMAGNETIC BREAKER This is NOT a master ON OFF switch The breaker is designed to protect the unit and the components in the event of an over current event You should NOT use it as a master ON OFF switch THE POWER CORD The TRITON requires an IEC C19 t...
Страница 6: ...lets Each duplex has a dedicated CCI filter that reduces noise from the components that are connected For best performance if there are four components or less connect each component to a separate duplex If there are more than four components group the components by function For example Connect a DAC and transport to Zone 1 and the preamp to Zone 2 BURN IN The power distributor is constructed usin...
Страница 7: ...expand the outlet capacity of the TRITON without performance compromises CONTACT ENHANCEMENT FLUIDS Contact fluids pastes and gels are NOT recommended for use with this unit Many of these types of products leave a residue that can contaminate or damage the contact metals over a period of time The products labeled as silver bearing grease or silver impregnated silicon are particularly harmful Some ...
Страница 8: ...I Noise Filters 4 OVER CURRENT PROTECTION Hydraulic electromagnetic breaker OUTLETS US Version 8 NEMA 5 20R AS Version 8 NEMA 5 20R EU Version 8 EU1 16R INPUT CONNECTORS IEC C20 WIRING SYSTEM Dual 11 AWG VTX Conductors ZPP DS Copper Buss System CDA 101 Copper Shunyata s ArNi Cryogenic Treatment CONSTRUCTION 16 Gauge Powder Coated Steel Chassis Anodized Aluminum Faceplate Vibration Dampening intern...