34
AFQm
Instruction Manual
3�8�1�- CONNECTING INDIVIDUAL DEVICES
To connect multiple individual devices in parallel, follow these steps:
1�-
Select the device that will operate as the “
master
”.
2�-
Connect the “
master
” device. The current transformers are only connected to the “
master
”
device.
3�-
Connect all of the “
slave
” devices.
Note:
Each devices must feature the protection elements indicated in section
“3.5.- CONNEC-
TION”.
4�-
Connect all of the devices using the communication cables (
Table 14
).
Table 14: Communication cable, devices in parallel�
Communication cable
RJ11 connector
Pinout
4
3 2
1
1:
Not connected.
2:
CAN A
3:
CAN B
4:
Not connected.
Note:
The communication cable must be a CAT 5 cable or higher.
Connect the
OUT
terminal from the “
master
” filter to the
IN
terminal from the second filter, the
OUT
terminal from the second filter to the
IN
terminal of the third, and so on (
Figure 28
).
OUT
IN
2
3
2
3
ON
R
BUS
OUT
IN
2
3
2
3
ON
R
BUS
ON
R
BUS
Figure 28:Connecting 3 devices in parallel, using the communication cable�
5�-
Configure the installation in the “
master
” device (see
“7.- CONFIGURATION”
)
6.-
Complete the configuration of the slave devices
(see
“7.- CONFIGURATION”
).
7.-
Enable the terminator switch for parallel connection,
R
BUS
(Terminal No 2 of
Table 11
and
Table 12
) in the bus end devices only. Then disable in the other devices.
Содержание AFQm Series
Страница 1: ...INSTRUCTION MANUAL Active Parallel Multi Function Filter AFQm M217B01 03 19B...
Страница 2: ...2 AFQm Instruction Manual...
Страница 103: ...103 Instruction Manual AFQm 608 812 1755 665 465 1890 Figure 98 Dimensions Cabinet type AFQm...
Страница 105: ...105 Instruction Manual AFQm 14 CE CERTIFICATE...
Страница 106: ...106 AFQm Instruction Manual...
Страница 107: ...107 Instruction Manual AFQm...