5.4.3
Mechanical parameters
This menu allows to set some mechanical parameters of the machine.
From “SETUP” menu press key:
The mechanical adjustments menu consists
•
X load adjustment
it allows to adjust the tag picking position along the X axis.
•
Y load adjustment
it allows to adjust the tag picking position along the Y axis.
•
Pusher load adjustment
It allows to adjust the picking point of the tag when pushed out from the loader
•
X emboss adjustment
it allows to align the zero of the embossing fields
plate
•
Y emboss adjustment
it allows to align the zero of the embossing fields with the bottom edge of the tag.
•
X unload adjustment
it allows to adjust position of release of the tagalong X axis.
•
Y unload adjustment
it allows to adjust position of release of the tag along Y axis
•
X stand-by adjustment
it allows to adjust starting position of the clamp along X axis
•
Y stand-by adjustment
it allows to adjust starting position of the clamp along Y axis
•
Reversed char
it allows to use a set of characters rotated of 180°
To change one of these parameters
on the external keyboard) then press:
5.
Human Machine Interface
Mechanical parameters [F3]
to set some mechanical parameters of the machine.
or
[F3]
In this option the axes offsets are defined, that is
the starting points of the axes are regulated so that
they coincide with the values of the coordinates of
the fields assigned both to the DOG TAG plates and
to the MEDICAL RED ALERT TAG plates.
Warning: assigning non-correct values causes the
malfunctioning of the embosser and possible
damages to some of its components, therefore we
strongly recommend that only sp
staff use it.
djustments menu consists in:
it allows to adjust the tag picking position along the X axis.
it allows to adjust the tag picking position along the Y axis.
picking point of the tag when pushed out from the loader
it allows to align the zero of the embossing fields with the left edge of the Medical Red Alert Tag
gn the zero of the embossing fields with the bottom edge of the tag.
to adjust position of release of the tagalong X axis.
to adjust position of release of the tag along Y axis
to adjust starting position of the clamp along X axis
to adjust starting position of the clamp along Y axis
use a set of characters rotated of 180°
ge one of these parameters, touch the screen on the field you want to change (
then press:
or
[F1]
OPERATOR MANUAL
Human Machine Interface
40
In this option the axes offsets are defined, that is
the starting points of the axes are regulated so that
they coincide with the values of the coordinates of
fields assigned both to the DOG TAG plates and
to the MEDICAL RED ALERT TAG plates.
correct values causes the
malfunctioning of the embosser and possible
damages to some of its components, therefore we
strongly recommend that only specialized technical
picking point of the tag when pushed out from the loader
with the left edge of the Medical Red Alert Tag
gn the zero of the embossing fields with the bottom edge of the tag.
on the field you want to change (or use the arrow