OPERATOR MANUAL
2.
General information
7
2.4
Electrical specifications
Power supply
100 Vac ± 10% 60 Hz or 230Vac ± 10% 50 Hz
Max Absorbed Current
8.0 – 4.0A max
Absorbed Power
800 W
Fuse (5x20 mm)
T 10A
Main controller
CPU Arm Cortex-A8 / RAM 256 MB, with flash-disk and file system
Linux O.S. based
Display
7” color touchscreen display with high resolution
2.5
Rating of the equipment and applicable standards
Over voltage category (OVC)
II
Class
I
Protection classification
IP X0
Pollution degree (PD)
2
Power Systems
TN
Protective building installation
20A
Equipment mobility
Stationary
Applicable standards
UL62368-1, 2
nd
Ed.
IEC 62368-1
IEC EN 55032:2015
IEC EN 55024:2010+A1:2014
IEC EN 61000-3-2:2014
IEC EN 61000-3-3:2013
2.6
Physical environment and operating conditions
Temperature
+5°C ÷ +40°C
Humidity
30% ÷ 90% not condensing
Max altitude
2000m
Transportation and storage temp -25°C ÷ +55°C
Working noise
Lower than 75 dB (A)
Environment
For indoor use only
2.7
Communication and software
Interface
USB 2.0 port (device and host), Ethernet, WiFi
Software
Linux based self enclosed software PowerTag PC application
proprietary software Windows 7/8/10
Protocol
Multiembosser Optional: Cim, Xon-Xoff, Stored Format default,
Stored Format Selected and Pound-Pound
Data format
50 fields of 42 characters each (Variable, Fixed data, Counters, etc.)