OPERATOR MANUAL
4.
Installation
22
4.5
Warnings and installation precautions
The identification plate located in the rear panel indicates the serial number, the type of machine, the
power voltage and the absorbed current. Thus, check that the power source is compatible.
Before turning the machine on, make sure that the clamp retainer pin has been removed and that all
cables have been properly connected.
The layout of the identification plate is as follows:
After the Corporate name on the plate there are 7 embossed fields described below:
Model: Embosser model
Type: Machine Type
V-nom: Power Voltage
Hz: Supply Frequency
Imax: Absorbed Current
SN: Serial Number
Made in Italy Year of construction
Fuse Rate: Rating of the fuse
If the supply voltage is more than 20% higher than base voltage, the safety quick-acting fuse might cut
off the current.
To replace it remove the power plug and insert the tip of a flat-topped screwdriver in the space at the
bottom of the plug entrance.
Lift the fuse holder extremely carefully until you can manually remove it.
Should it be necessary, please contact the Technical Service of MF Group – CIM division.
TO REPLACE THE FUSE USE ONLY FUSES OF THE SAME TYPE AND WITH
THE SAME NOMINAL POWER.
Fuses Requisites:
Europe - IEC 60127 Approval
America - UL248-1 and UL248-14 Approval