24VAC
POWER FOR
FLOOD PUMP
CONTACTOR COIL
24H-515 RED
24H-503 RED
24N-510 BRN
24H-515 RED
T4
L4
14NO
13NO
22NC
21NC
T3
L3
T2
L2
T1
L1
COIL
18 AWG
24N-516 BRN
18 AWG
18 AWG
18 AWG
16
6
A
OAK 3 PHASE FLOOD PUMP CIRCUIT
160523
OAK SET.dwg
SPM
A
B
C
D
A
B
C
D
1
2
3
4
1
2
3
4
(814) 353-9256 www.centroidcnc.com
Copyright © 2016 Centroid
Title
Size
Rev
Drawn by
Date
Filename
Sheet
of
NUMBER
3
REV
DATE
DESCRIPTION
BY
1
5-23-2016
INITIAL RELEASE
SPM
2
6-8-2016
CONTACTOR PN, BOARD DEPICTION
SPM
3
6-17-2016
ADDED NOTE 2 FOR CONTACTOR SNUBBER
SPM
220-214 BLK
220-215 BLK
220-216 BLK
220-217 BLK
220-218 RED
220-219 WHT
L1
T1
L2
T2
L3
T3
13NO
14NO
COIL
T1
T2
T3
97NO
95NC
98NO
96NC
L1
L2
L3
FLOOD
PUMP
MOTOR
3-PHASE
SNUBBER
PN:12610
220VAC
3 PHASE POWER
FOR FLOOD PUMP
12 AWG
OVERLOAD
PN:3959
(24VACN)
(24VACH)
(24VACH)
(24VACN)
3
9 IN
10 IN
11 IN
12 IN
9 - 12 COM
13 IN
14 IN
15 IN
16 IN
13 - 16 COM
+24VDC
24V COM
AN OUT
AN GND
H1
H14
H2
SIP 2
OPTOS
SIP 1
OPTOS
H11
OUT 1 COM
OUT 2 COM
OUT 3 COM
OUT 4 COM
OUT 5 COM
OUT 6 COM
OUT 7 COM
OUT 8 COM
OUT 9 COM
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8 N0
OUT 8 NC
OUT 9 NO
OUT 9 NC
1
2
3
4
5
6
AN GND
AN IN
L1
L2
L3
FG
E-STOP CONTACTOR
W/ SNUBBER PN:14374
SEE NOTE 1
FLOOD PUMP
CONTACTOR
W/ SNUBBER PN:14377
DRIVE
COM OUT
ENC 6
H8
1
H9
2
H10
3
H12
4
H7
ENC 5
PLC ADD CONNECTORS
NOTE 1
ALL CONTACTOR COILS REQUIRE A
SNUBBER, EITHER CONTACTOR
MANUFACTURERS RECOMMENDED
SNAP ON SNUBBER OR CENTROID
PN:1819 EXTERNAL QUENCHARC
SNUBBER.
GND
GND
A2
A1
A2
A1
A2
A1
LC4D
REV 150209
OAK
PN:13135
Содержание OAK