Appendix C: Troubleshooting Errors Reported By CNC11
Symptom or Error
Lube Fault
3. Lube Fault
This fault is caused by the Lube Fault PLC input (9)
being open. Go to the main screen in CNC11 and bring up the real-time
I/O screen to view the state of input 9. If input9 is red, your lube pump is
reporting a fault. To clear this fault, add lube to your lube pump until
input 9 turns green or check the wiring and/or float switch for proper
operation. Once input 9 is again green, the Estop switch/input must be
cycled to clear the fault.
Symptom or Error
Limit Tripped
4. Limit tripped messages
Limit tripped messages (for any axis)
indicate that a PLC input that has been configured as a limit switch input
in the motor configuration screen is open. To troubleshoot, two things
will need to be checked.
#1 What are the limit switch settings in the motor configuration screen?
Enter the motor configuration screen and record the current limit switch
settings for both + & -. From the main screen press
F1-Setup
→
F3 Config, pw = 137, Press enter
→
F2 Mach
→
F2 Motor