7. Bench Testing the MPU11 and GPIO4D
3. Testing the analog outputs for each axis
The GPIO4D outputs -10 to +10VDC signals
for control of up to 4 axes. When testing the -10 to +10VDC analog output for each axis,
place your probes in the appropriate location as indicated below for the axis being tested.
Remember to tighten down the terminals before when measuring voltage.
Probe between Analog Out(+) and Analog
COM(-) at the locations indicated each
axis.
Each axis is tested from 0 to +10VDC and
from 0 to -10VDC in 2.5VDC increments. In
total, 8 measurements are made for each
axis. Enter your readings as prompted.
Bench Testing Completed. Power off and disconnect the components.