Appendix B - Allow Communication with LTE Gateway
84
MLGPS-P
User's Guide
Appendix B - Allow Communication with LTE Gateway
To allow other communication devices, such as an LTE cellular modem, to provide communications to the
MLGPS module, the internal Wi-Fi adaptor must be turned off and the GPS RS-232 port must be enabled for
communications.
Follow these steps to enable communication between the MLGPS unit to an LTE Gateway such as the AirLink
RV50.
1. Using the GPS RS-232 port on the right side of the device, connect the MLGPS unit to a computer. This is
done using a Null-Modem cable.
(Figure B 1)
2.
Open Campbell Scientific’s Device Configuration Utility and select
Unknown
from the list of Device Types.
3. Select the correct COM port and set the Baud Rate to
115200
.
(Figure B 2)
4. Click
Connect
to open the Terminal tab.