Section 4 - MultiLogger Configuration
MLGPS-P
User's Guide
45
Station Settings
The
Station
options allow for the selection of the Station Type and sampling rates for the station. Select
Rover
as the
Station Type
.
(Figure 4.3.2 B)
It is recommended that Rover Stations keep a default value of
1 second
for the
Position Sampling Rate
for
the best solution quality, more samples per period results in a more precise solution. For the
Status Sampling
Rate
, an interval that is practical for data storage, such as fifteen minutes, should be selected.
Configure Offline Mode
See "Configure Offline Mode" in section
4.3.1 Base Station Configuration