Section 4 - MultiLogger Configuration
MLGPS-P
User's Guide
69
Table 4.4.7 A outlines a list of terminal commands:
Command
Return
MLGPS_BAT
Get battery voltage
MLGPS_CHG
Get charge voltage
MLGPS_CLB
Calibrate current sensor
MLGPS_COM
<PORT>
<PORT>
Defines the active interface where:
SERIAL
-
Switches control to OEMSTAR’s port
1
and turns
off
the power of the
M2M module (adaptor)
TCP
– Switches control to OEMSTAR’s port
2
and turns
on
the power of the
M2M module (adaptor)
MLGPS_CUR
Get charge (+) or discharge (-) current
MLGPS_FRST
Factory reset
MLGPS_GPS
Get GPS position status
MLGPS_HELP
Show list of commands
MLGPS_HMD
Get humidity
MLGPS_LIC
Turn on / off Low Insolation Compensation. Syntax: MLGPS_LIC [N|Y]
MLGPS_LOGL
Get/Set logging level. Syntax: MLGPS_LOGL [DEBUG|INFO|WARNING|ERROR|FATAL]
MLGPS_LOGN
Get last N records from log. Syntax: MLGPS_LOGN <records count>
MLGPS_LOGP
Turn on/off pushing log events. Syntax: MLGPS_LOGP [N|Y]
MLGPS_RM
Get/Set radio mode. Syntax: MLGPS_RM [power_on_interval, power_on_offset,
idle_interval]
MLGPS_RST
Hardware reset
MLGPS_SMR
Get/ Set sample rate. Syntax: MLGPS_SMR [position rate, status rate]
MLGPS_SN
Get/Set serial number. Syntax: MLGPS_SN [serial number]
MLGPS_TEMP
Get temperature
MLGPS_TIME
Get GPS time
MLGPS_VER
Get firmware version
MLGPS_VMP
Get/Set solar maximum power voltage for 25 deg. Syntax: MLGPS_VMP [voltage]
(Table 4.4.7 A)