AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 302 of 402
Command Syntax
SYSTem:DIO:OUTput[n]:INVert
Description
Inverts the logic polarity of the selected digital output.
Parameters
[ 0 | NORMAL | 1 | INVERT ]
Example
SYST:DIO:OUT1 1
Query Format
SYSTem:DIO:OUTput[n]:INVert?
Description
Returns logic inversion setting
Returned Data Format
<nr1>
Query Example
SYST:DIO:OUT1:INV?
1
Query Format
SYSTem:DIO:OUTput[n]:STATe?
Description
Returns logic level of selected output pin.
Returned Data Format
<b>
Query Example
SYST:DIO:OUT1:STAT?
1
8.10.1.5
SYSTem:DIO:REMote
Command Syntax
SYSTem:DIO:REMote:ENAble <b>
Description
Turns the remote enable state on or off
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
SYST:DIO:REMote:ENAble 1
Query Format
SYSTem:DIO:REMote:ENAble?
Returned Data Format
<b>
Query Example
SYST:DIO:REM:ENA?
1
Command Syntax
SYSTem:DIO:REMote:INHibit <b>
Description
Turns the remote inhibit state on or off
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
SYST:DIO:REMote:INHibit 1
Query Format
SYSTem:DIO:REMote:INHibit?
Returned Data Format
<b>
Query Example
SYST:DIO:REM:INH?
1