AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 314 of 402
Command Syntax
*ESE<nr1>
Description
Selects the desired bits from the standard event status enable
register. The variable <nr1> represents the sum of the bits that will
be enabled.
This register monitors I/O errors and synchronization conditions such
as operation complete, request control, query error, device
dependent error, status execution error, command error and power
on. The selected bits are OR’d to become a summary bit (bit 5) in the
byte register which can be queried. The setting by this command is
not affected by *RST. However, cycling the power will reset this
register to zero. Refer to section 8.12 for register bit values.
Parameters
Range 0-255
Parameter Format
<nr1>
Example
*ESE 128
Query Format
*ESE?
Returned Data Format
<nr1>
Query Example
*ESE?
193
Query Format
*ESR?
Description
Event Status Register Query. Reads the contents of the Status Event
Register (ESR). After this query, the content of the ESR register is
reset. Refer to section 8.12 for register bit values.
Returned Data Format
<nr1>
Query Example
*ESR?
0
Command Syntax
*GTL
Description
Goto Local. Releases lock of front panel controls.
Returned Data Format
N/A
Query Example
N/A
Query Format
*IDN?
Description
Identification Query. Returns the unit’s Identity string. The IDN string
response contains several fields separated by a comma.
Query response: Manufacturer, model, serial number, firmware
revision.
Returned Data Format
<cr>,<cr>,<nr1>,<nr2>
Query Example
*IDN?
PPSC,3150AFX-2AG,106378889,2.0.0
Command Syntax
*LLO
Description
Local Lock out. Locks out front panel LOCAL function.
Parameters
None
Parameter Format
n/a