10.8.6
Scope
The Scope function captures voltage and current waveforms at the output of the power source
on all phases. This screen allows a variety of captured waveforms to be displayed.
The following controls are available to customize the captured waveform display:
CONTROL
Purpose
MEASUREMENT
Selects Voltage, Current or Both
PHASE
Selects Phase A, B, C or all (ABC). Only visible in two or three phase mode.
UNIT
Selects time scale in either TIME, SAMPLES or PHASE
PERIODS
Selects the number of periods to display. Range is 1~ 4
AUTO REFRESH
Turns AUTO REFRESH mode ON or OFF
REFRESH PERIOD
Sets interval time for AUTO REFRESH mode in seconds. Range is 5 ~ 100.
REFRESH
Manual REFRESH button
EXPORT GRAPH
Downloads image for displayed waveform(s). See sample below.
EXPORT DATA
Downloads captured data points for displayed waveform(s) in csv format text
file. See sample below.
Sample
Degrees
Time[s]
Phase A -
Voltage[V]
1
0
0
-0.12
2
0.7
3.91E-05
0.05
3
1.41
7.81E-05
0.02
4
2.11
0.000117
-0.1
5
2.81
0.000156
-0.03
6
3.52
0.000195
0