AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 247 of 402
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MAXimum?
Description
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MAX?
254.946
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MINimum?
Description
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MIN?
-254.946
Command Syntax
[SOURce:]VPEAK:MARGin
Description
This command sets the over voltage protection trip level as an
absolute value. Thus, if the output voltage exceeds the programmed
v the Vpeak Margin, the OVP protection will trip off the
output and generate an OVP fault.
For example., if 230Vrms is programmed in AC mode and the Vpeak
margin is set to 20, the OVP will trip at 230 *
2 + 20 =345Vpeak.
Parameters
0.0 – 500.0
Parameter Format
<nr2>
Example
VPEAK:MARG 20.0
Query Format
[SOURce:]VPEAK:MARGin?
Returned Data Format
<nr2>
Query Example
VPEAK:MARG?
20.0000
Command Syntax
[SOURce:]VOLTage:EXTend
Description
This command grants access to a higher voltage range extension
mode. When enabled, AC voltage settings up to 333V L-N are
supported.
Parameters
[ 0 | OFF | 1 | 2 ]
0 = Off, 300Vac max.
1 = 312Vac max
2 = 333Vac max
Parameter Format
<bool>
Example
VOLT:EXT 1
Query Format
[SOURce:]VOLTage:EXTend?
Returned Data Format
<nr1>
Query Example
VOLT:EXT?
1