AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 376 of 402
12
Warnings & Error Messages
12.1
Preface
During normal operation, a series of error and/ or warning messages may be displayed on the
front panel LCD display or reported by the error queue over one of the remote control
interfaces. This section of the manual lists available warning and error messages in numerical
order and provided some additional information on their meaning and possible causes. Where
relevant, suggested remedies to resolve any conditions are included as well.
Note: There are some Error and Warning messages that may appear in the Errors & Events
that are NOT listed in the next section. In case you encounter an unlisted error or
warning message and code, contact Pacific Power customer service
(
) and describe the number and description to obtain further
information.
After reporting such an event, try rebooting the power sources by cycling power as most
of these conditions will clear up with a reboot.
12.2
Errors & Warnings Messages in Numeric Order
Error Source
Code
Category
Error Message
Possible Cause
Resolution
Front panel
Error
-500
Event
Event: Power ON.
Power on event detected.
Normal after power on
Not needed
Front panel
Error
-360
Remote
Communication error
with an interface.
Internal Communication
Error between front panel
and power stage. Bad
connection
Try recycling power. If
error persists, contact
customer service
Front panel
Error
-350
Event
Error & Event (E&E)
queue overflow.
Events and Error queue is
full. Too many errors or
events
Clear the Error & Event
(E&E) Queue
Front panel
Error
-320
Error
Storage fault.
Memory error detected
by front panel processor.
Memory Checksum error
Try recycling power. If
error persists, contact
customer service
Front panel
Error
-310
Error
System error
Unknown System Error.
Cause Undetermined
Try recycling power. If
error persists, contact
customer service
Front panel
Error
-290
Remote
Execution error: Memory
use error.
Incorrect Memory Access.
Cause Undetermined
Try recycling power. If
error persists, contact
customer service
Front panel
Error
-286
Remote
Execution error: Not
allowed command with
the current configuration.
Configuration setting
related conflict.
Check configuration
settings
Front panel
Error
-285
Remote
Execution error: Program
syntax error.
Incorrect command
syntax
Check syntax
Front panel
Error
-284
Remote
Execution error: Program
is currently running.
Trying to start a program
that is already running