AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 261 of 402
Command Syntax
[SOURce:]WAVEFORM#:LOAD
Description
Sets the waveform name (1 – 16) to be loaded for the selected phase
# for the next SWITCH command. If # is omitted, sets all available
phases to waveform name specified.
Note: The waveform LOAD command loads the selected phase’s
waveform registers with the waveform data for the specified
waveform name but does not cause it to appear at the output until
the WAVEFORM:SWITCH command is received.
Parameters
1 – 16
Parameter Format
<nr1>
Example
WAVEFORM2:LOAD 12
Query Format
[SOURce:]WAVEFORM#:LOAD?
Returned Data Format
<nr1> or <nr1>,<nr1>,nr1>
Query Example
WAVEFORM:LOAD?
1,12,1
Command Syntax
[SOURce:]WAVEFORM#:SWITCH
Description
When sent for the selected phase, the output waveform is switched
over to the new waveform name that was last set with the
WAVEFORM#:LOAD command. . If # is omitted, sets all available
phases’ waveforms are switched.
Parameters
None other than phase selected in command string
Parameter Format
n/a
Example
WAVEFORM1:SWITCH