AFX SERIES® OPERATION MANUAL
SECTION 10:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 361 of 402
Grouping
Controls
Analog Inputs:
CHANNEL
[ 1 | 2 | 3 | 4 ]
INPUT VOLTAGE
Displays read back voltage
COMMAND
Select command from dropdown list
or OFF for none
RANGE
0.0000 – 10.000 V
GAIN
Gain
OFFSET
Offset value
Analog Outputs:
CHANNEL
[ 1 | 2 | 3 | 4 ]
OUTPUT VOLTAGE Output setting
MEASUREMENT
Select measurement to be assigned
to output
RANGE
0.0000 – 5.000 V
GAIN
Gain 0.000 - 1000
OFFSET
Offset value – 1000 ~+1000
Digital Inputs:
CHANNEL
[ 1 | 2 | 3 ]
STATE
Displays input state
RISING CMD
Set command string to execute on
rising edge
FALLING CMD
Set command string to execute on
falling edge
FILTER SIZE
0 – 10,000,000 msec
Digital Outputs:
CHANNEL
[ 1 | 2 | 3 | 4 ]
STATE
Displays current state
FUNCTION
Assigns state to selected channel.
Available states are:
FAULT
FORM
HIGH
LOW
OUTPUT STATE
PROGRAM
REMOTE
TRANSIENT
INV. LOGIC
[ ON | OFF ] Reverses polarity