background image

DHY

12000SE(-3)

DHY

15000SE(-3)

USER MANUAL

REVIEW MANUAL CAREFULLY TO AVOID PERSONAL INJURY

MADE UNDER LICENSE OF HYUNDAI CORP. SEOUL, KOREA

EN

DIESEL POWER GENERATORS

Summary of Contents for DHY12000SE(-3)

Page 1: ...DHY12000SE 3 DHY15000SE 3 USER MANUAL REVIEW MANUAL CAREFULLY TO AVOID PERSONAL INJURY MADE UNDER LICENSE OF HYUNDAI CORP SEOUL KOREA EN DIESEL POWER GENERATORS...

Page 2: ...INDEX 1 SAFETY INFORMATION 2 COMPONENTS 3 CHECK BEFORE USE 4 START OF THE ENGINE 5 STOP OF THE ENGINE 6 MAINTENANCE 7 PROBLEM SOLUTIONS 8 SPECIFICATIONS 9 GUARANTEE 10 NOTES 1 2 4 5 6 6 9 10 16 16...

Page 3: ...2 Never stop the generator when is load applied be sure to disconnect any apparatus from the generating set prior start of prior stop 13 Do not allow children to operate the engine Keep children and p...

Page 4: ...2 Any flammable or explosive product shall be kept away from the generator due to the high temperature of the engine 3 Install your group on a flat horizontal surface to avoid spilla ge of gasoline 4...

Page 5: ...p 4 Air filter cover 5 Control panle 6 Fuel filter 7 Fuel valve 8 Speed gobernor 9 Oil Dipstick 10 Battery 11 Muffler 12 Wheels 13 Oil filter 1 Plate 2 Main breaker 3 Controller fuse 2A 4 Contactor Ke...

Page 6: ...haust gas sucked by the person the diesel genera tor will be not allowed to work under condition of worse ventilation because exhaust gas emitted from the engine includes harmful CO 3 1 3 Preventing t...

Page 7: ...m retight the screw Remember to clese the fuel valve before drain the water from the fuel filter 3 2 2 Filing the lube oil The qualified lube oil should meet following condition ACEA B2 E2 or higher g...

Page 8: ...e should check oil level If not being enough should add the lube oil to the stipulated level Draining off lube oil can be immediately done after engine stopped because it is difficult to drain off the...

Page 9: ...like lamp and motor etc Before starting the generator must turn off main switch If not in this position it is very dangerous for the generator to be started with the load so can damage the AVR and th...

Page 10: ...n running in order to keep the battery recharge If longer time not starting the generator the battery can go out of charge so a exter nal charger should be used in order to complete the charge Please...

Page 11: ...umulator will drop to cause the motor to be blocked During the operation let the key be in ON position 6 If the control panel is intelligent type also please refer to its manual 7 For remote control s...

Page 12: ...eck the color of exhaust gas black or too white If any of them mentioned before occurs you should stop the generator and then contact with local dealer 7 When voltage indicating on control panel reach...

Page 13: ...accumulator the charging current should be less than 8A Otherwise the fuse will burn 4 During charging the accumulator will make inflammable gas So place away spark flame and cigarette To avoid spark...

Page 14: ...r diesel level warning when the diesel fuel level is low the red lamp will turn on the generator will stop if the level is continuously low for 20 minutes meanwhile the red lamp twinkles 5 Green lamp...

Page 15: ...me H 5 Temp degrees Celsius 6 Disuse 7 Software release If lamp 8 is on auto protection is effective otherwise auto protection is ineffective If lamp 9 is on diesel valve is power up If lamp 10 is off...

Page 16: ...protection setting is ineffective the voltage digital code will twinkle and the generator will not stop 2 Frequency protection 50Hz 47 55 60Hz 57 65 If the value exceed the limits the frequency digita...

Page 17: ...iesel generator is consisted of diesel engine alternator control panel frame etc Before maintaining the generator stop the engine You should perform the maintenance in a well ventilated area After sto...

Page 18: ...erytime the oil is change Please refer to point 3 2 3 for detailed information NOTE Do not clean the filter element with detergent 6 4 Change of fuel filter TIME INTERVAL every 500 hours replace for a...

Page 19: ...ust proofed oil or lube oil without water into intake mani fold and then rotate the engine rapidly Last make intake exhaust valve be at close state 6 Dismantle cylinder head cover and brush rock arm e...

Page 20: ...ntact of the socket Not reach rated speed of the engine Not reach rated speed of the engine Check AVR 1 lack of the fuel 2 lack of lube oil 3 voltage too low too high 4 frequency too low too high 5 ov...

Page 21: ...x16A 1x32A 1 LED5 21 18 76 12 8 3 36 Diesel D840E 22 Elec star 836 1 7 A9 1S 9 1 AVR 245 280 30 64 94 50 10 9 kVA 11 9 kVA 400 16 6 1x16A 3 1x16A 1 1 LED5 21 18 76 12 8 3 36 Diesel D840E 22 Elec star...

Page 22: ...GUARANTEE This generators are guaranteed for any failure or defect of fabrica tion for a period of 1 year or 1000 hours Non respect of the instructions in this user manual will avoid the guarantee 10...

Page 23: ...21...

Page 24: ...MADE UNDER LICENSE OF HYUNDAI CORP SEOUL KOREA by...