4.3.8 Remove the template(s). Add the wooden stakes and level them.
4.3.9 Place the wire mesh (6 x 6, 4 gauge). Be sure the wire mesh is centered vertically.
Note: No. 3 (
3
/
8
-inch or 9 mm) or larger reinforcing rod, placed on 15-inch (38.1 cm)
centers, may be used in place of wire mesh.
4.3.10 Place the MESA
®
6 NxT / Calix ODC-120 template in the form and over the conduits. If used,
place the JuiceBox template into the form and over the 1
3
/
4
-inch conduit.
4.3.11 Fasten the template(s) to wooden stakes as shown in Fig. 10.
CAUTION
Make certain the MESA
®
6 NxT / Calix ODC-120 cabinet template is flat and level to prevent
misalignment of cabinet doors.
4.3.12 Square and level the template(s) on the stakes so the tops of the mounting plates are flush with,
or no more than
1
/
4
-in. (6 mm) above, the top of the pad (Fig. 11). Square the template(s) so
the diagonal measurement between the anchor bolts is equal.
Note: The cabinet must clear the finished concrete surface so that the base panel below
the cabinet end chamber can be removed.
4.3.13 The conduit should extend approximately two inches (5.08 cm) above the template (Fig. 11).
Cover the conduits at the top to keep concrete from entering them during the pour.
Note: Make sure the conduit ends extend vertically through the template (perpendicular
to the template surface).
4.3.14 Before pouring concrete, be sure that all eight
1
/
2
" x 13 anchor bolts in the MESA
®
template
are threaded all the way down in the anchor nuts.
ELECTRICAL CONDUIT
EXTENDING 2" (50.8 mm) ABOVE
CONCRETE PAD
CABLE CONDUITS
2" (5.08 cm) ABOVE
CONCRETE PAD
CABINET TEMPLATE
FLUSH WITH, TO 1/4" (6.4 mm)
ABOVE TOP OF CONCRETE
2" (5.08 cm)
2" (5.08 cm)
2" (5.08 cm)
WOODEN FORM
(2 x 6) TYPICAL
6" (15.24 cm)
CONCRETE PAD
NOTE:
If pole-mounted power transfer switch is used, delete power
pedestal opening and conduit, and extend AC power conduit
12" (30.5 cm) beyond concrete pad in direction shown on
engineering drawings.
WELDED MESH
6 X 6 X 4/4 (4 GAUGE WIRE)
GROUND WIRE TO
GROUNDING SYSTEM
COMPACTED
SOIL
SAND
OR GRAVEL
16" STAKES
Fig. 11 : Position of Conduit in Template