MODEL 1030-00
Installation Instructions
**** WARNING ****
Please thoroughly read the product warning below
before installation to provide for a safe work
environment.
1. This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not
exceed this temperature, depending on power dissipation within enclosure.
2. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be
maintained for the safe operation of the equipment.
3. This product is intended to be installed by trained personnel.
4. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or
replacement.
5. Maximum weight to be installed in the unit is 25 lbs.
6. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that
complies with UL 2043 or UL 1479.
7. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.