4.3 Form Preparation
4.3.1 If the soil is not firm, compact it. For excavated pad applications, clear an area for the pad and
cable conduits in accordance with the engineering work prints. For a typical installation,
excavate the foundation hole to a depth of 12 to 16 inches (30.48 to 40.64 cm).
4.3.2 Construct a level base for the pad, using a minimum of six inches (15.2 cm) of sand or gravel.
The pad should be level to within
1
/
4
-inch (6 mm) over the entire length and width.
4.3.3 Dig a trench to the area where the cable and electrical conduit will rise into the MESA
®
6 NxT
/ Calix ODC-120 cabinet (Fig. 10). Excavate the trenches to a depth of 30 inches (76.2 cm) for
a standard installation, and 60 inches (152.4 cm) for areas where there is heavy frost.
— If using a separate power transfer pedestal, dig a trench for the electrical conduit
going from the cabinet to the power transfer pedestal.
— If using a pole-mounted AC source, dig a trench for the electrical conduit from the
cabinet to the pole.
FRONT SIDE
OF CABINET
5.00"
(12.7 cm)
19.63" REF
(49.66 cm)
18.00" REF
(45.72 cm)
5.88"
(14.94 cm)
21.50" REF
(54.61 cm)
24.76" REF
(62.89 cm)
1.00" REF
(2.54 cm)
6.63" REF
(26.52 cm)
9.89" REF
(25.12 cm)
FRONT SIDE
OF CABINET
6.25"
15.88 cm)
19.87" REF
(50.47 cm)
18.00" REF
(45.72 cm)
7.10"
(18.03 cm)
21.50" REF
(54.61 cm)
10.44" R
E
F
(26.51 cm
)
13.70" R
EF
(34.79 cm
)
1.00" REF
(2.54 cm)
24.76" REF
(62.89 cm)
Fig. 8 : Power Transfer Pedestal Mounting Templates
JuiceBox
Содержание ODC-120
Страница 1: ...Calix ODC 120 Installation Guide June 2005 220 00050 Rev 12...
Страница 4: ......
Страница 6: ......
Страница 44: ......