Operation
Butzbach GmbH Industrietore
Originalbedienungsanleitung NOVOSPRINT_V1
24/02/2021
27
7
Operation
This chapter shall make the system user familiar with the proper operation of the door system.
When operating the door system, the safety information and warnings in chapters 2 Safety and 3 Other dangers
must absolutely be followed!
7.1
Electrical connection
7.1.1 Requirement
According to the European standard for
“Safety for the use of power-operated doors - requirements”, the
connection to the mains must be done with an isolation device, which shuts off all poles and is secured
against being turned on again (lockable).
The installed main switch fulfils the function of an
“isolation device” and simultaneously serves as an
emergency control device (red button on a yellow background) as required by the national applicable
guideline ASR A1.7 (previously BGR 232) for power-operated windows and doors.
1.
Secure the power connection (1/N/PE 230 V) with a circuit breaker (if nothing is otherwise specified:
type C, value 16A).
2.
When using an FI circuit breaker, ensure that a type B circuit breaker with rated fault current of a min.
300mA is used.
FI circuit breaker symbol:
7.1.2 Connection
1.
Connect the mains supply line to the input terminals in the switch box (see the circuit diagram).
2.
If you want to connect additional control devices or photo eyes, proceed according to the circuit
diagram.
The three phase control is omitted in the case of connecting to single phase current.
7.1.3 Commissioning
1.
The standard setting is automatic operation: the door automatically closes after the parametrizable
closing delay time passes. Other types of operation and the length of the closing delay time can be
selected as parameters.
2.
Turn on the main switch. The display lights for approx. 5 seconds after operating the main switch. The
door is ready for operation.
Warning! Injuries and damage when working on the system!
Make sure that electricity has been disconnected from the control unit when working on the system. Risk
of injury and risk of damage!
Ensure that the main power switch is guarded against being turned back on without authorisation
with a hanging lock and that the CEE plug is guarded against being plugged in.
If multiple people are working on the system,
each one
must ensure that the main power switch
is secured against being turned on without authorisation.