14
z
Check the cable between the plug and socket
connection and the 81-pole plug in the UBA3 instal-
lation base (see fig. 58) using a circuit continuity
testing device.
See the electric circuit diagram, fig. 25 on page 26.
z
Test this in a straight line twice and test it diagonally
twice.
z
Restore the plug and socket connection if the cables
are OK.
z
Install the UBA3.
z
Fit the casing.
z
Connect the heating system to the power supply,
insert the main fuse or switch on the circuit breaker.
z
Set the main switch on the BC10 to "1" (On).
14.10 Checking the hot surface ignitor;
Control
z
Disconnect the heating system from the power
supply, remove the main fuse or switch off the circuit
breaker.
z
Set the main switch on the BC10 to "0" (Off).
z
Remove the casing.
z
Disconnect the plug and socket connection of the hot
surface ignitor.
z
Set the measuring device to 120 VAC.
z
Connect the measuring device to the plug on the
cable harness.
z
Connect the heating system to the power supply,
insert the main fuse or switch on the circuit breaker.
z
Set the main switch on the BC10 to "1" (On).
z
Start up the appliance.
z
Test that during the ignition phase, while the oper-
ating code
.</D
is being displayed, 120 VAC is
measured.
z
Disconnect the heating system from the power
supply, remove the main fuse or switch off the circuit
breaker.
z
Set the main switch on the BC10 to "0" (Off).
z
Remove the measuring device.
z
Assemble the plug and socket connection of the hot
surface ignitor.
z
Fit the casing.
z
Connect the heating system to the power supply,
insert the main fuse or switch on the circuit breaker.
z
Set the main switch on the BC10 to "1" (On).
Fig. 58
UBA3 installation base
Pin
1
28 55
Pin
81
Pin
16
Pin
1
KIM
16-pole connector