For this kind of door lock, an additional power supply must be used . The connection method is shown below .
The Power supply in the above drawing is the system riser power supply . It can be shared by the riser shunt without the need
for an auxiliary Power supply . The power supply is the auxiliary EP power supply (in some cases the riser has several EP . In this
case auxiliary power supply will be needed; additional power supply is also needed if the main EP cable is too long) . The door
lock accessory can be directly connected to this power supply without the need for an additional one .
cable type
2 x 1.0 mm
2
cable type
2 x 1.0 mm
2
Max distance
≤ 20 m
Max distance
≤ 250 m
EP/WEP
Lock
L-L+
L-
L+
Power
supply
323015
Door lock release
GND
Power
30V
GND
GND
Lock type and distance limits