coDe For the conFiguration place
F F I
I #I #I
Configuration methods using the pushbuttons
1 . Enter into the configuration status: In standby, press key
(S2) for 2 seconds to enter configuration mode, the CFG
indicator will be on (If the configurator is fitted with a
resistor or the pushbuttons are incorrectly configured,
access to configuration mode is not possible) .
2 . Enter the configuration place code (to select a certain
place at the configurator): press the S2 key to reach
the desired number . At every pressure the code will be
increased by one 1 (no pressure will give 1) and the CFG
indicator will flash once .
3 . Confirm the configuration place code: Press the S1 key
and the CFG indicator will flash quickly twice . Then it
emit an extended flash to and enter value configuration
mode .
4 . Enter the configuration place value: Press the S2 key
(defaulted at 0) . Press once and the value will be
increased by 1, the CFG indicator flashing quickly twice .
5 . Confirm the configuration place value: Press the S1 key
and the CFG indicator will flash quickly twice; than it
flashes slowly twice, the value is set .
6 . Set the next place: If you need to set the value of other
configuration places, press S2 and the CFG indicator will
flash 3 times . Then continue from point (2) .
7 . End the configuration: Press the S1 key to exit
configuration mode . If the procedure has been successful
the CFG will flash once and then come on steady . The
new configuration is now available . If the procedure
fails (for example, a certain configuration value is bigger
than 9), the CFG indicator will go off and then come
back on using the old configuration . If the configuration
value is logically wrong (such as II>#II), then on reset
the CFG indicator will flash quickly, indicating wrong
configuration and pushbutton operation will stop .
In this case connect the non-zero (1 to 9) resistor to
the configurator and repower to clear all the values
configured using the pushbuttons . Remove the resistor,
repower and reset following the above steps . If during
the operation no pushbutton is pressed for 10 seconds,
the unit will automatically exit the configuration status
and the CFG indicator will go off .
Methods for viewing the configuration
(You can only view the information configured with
the pushbuttons or RS232 ) .
1 . Switch to view status: In standby, press the S1 key
for 2 seconds and the CFG indicator will flash slowly
and enter configuration view mode (This status is
not accessible in case of wrong configuration) .
2 . Enter the configuration code (to select a certain
place at the configurator): press the S2 key to
increase the numbers . At every pressure the code
will be increased by one 1 (no pressure will give 1)
and the CFG indicator will flash slowly twice .
3 . Read the configuration value: Press the S1 key and
the CFG indicator will flash . The number of times it
will flash will depend on the size of the value (For
example, if the reading result is 0, it won’t flash; if
it’s 1, it will flash once, and if 2, it will flash twice,
and so on), and then move to the next step .
4 . With the CFG indicator off, it will exit the
configuration view status: If during the operation
no pushbutton is pressed for 10 seconds, the unit
will automatically exit the status and the CFG
indicator will go off .