17
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
hanDsets user settings
FuncTional lisT For seTTing and channel alarMs
seTup iTeM
operaTion code
nexT operaTion
Meaning and inForMaTion For The operaTion
reMark
Change user password
99#
First input“XXXX#”
Note 1
Then input“XXXX#”
If the passwords input are the same: 1 long tone, otherwise 3 short tones
*
Return to the main setup menu, 1 short tone
other keys
Unsuccessful operation: 3 short tones
2 Select ring tone for calls
from system 92#, 93# note 2
92#, 93# please refer to note 2
91#
“XX#” or“X#”
Succesful selection: play the selected tone
Ineffective selection: 3 short tones, play the original tone
Note 1
*
Return to the main setup menu, 1 short tone
Note 2
other keys
Unsuccessful operation: 3 short tones
Disable zone or enable zone
(Defense area)
1#
0
Disable zone 1: LED 1 off, 1 long tone
1
Enable zone 1: successful, LED 1 turn on, 1 long tone; unsuccessful 3 short tones.
Note 1;
Reason for
unsuccessful
zone enable,
note 3.
*
Return to main setup menu, 1 short tone
other keys
Unsuccessful operation: 3 short tones
…
…
…
8#
0
Disable zone 8: LED 8 off, 1 long tone
1
Enable zone 8: successful, LED 8 on, 1 long tone; unsuccessful 3 short tones.
*
Return to main setup menu, 1 short tone
other keys
Unsuccessful operation: 3 short tones
Enable or disable all zones
with shortcut key
If has any zone is already enabled, this operation will disable all the burglar zones, 1 long tone will be heard.
Note 1;
Reason for
unsuccessful
zone enable,
note 3.
If all zones are disabled, this operation will enable all the zones connected to sensors
.
if the operation is successful, 1 long tone; if not, 3 short tones.
*
Quit setup mode: 1 short tone
other
Unsuccessful operation: 3 short tones
Note 1: set default parameter and setting range
Items
default parameter
setting range
User’s password
2000
0000-9999
System ring tone
tone 1
1-12
Ring tone for calls from EP
tone 2
1-12
Ring tone for internal calls
tone 3
1-12
Note 2: the code to set the ring tone for calls from Small EP is 92#; the code to set the
ring tone for internal calls is 93#; other operations are performed using the same
method as the method to set the ring tone for calls from the system.
Note 3: reason why enabling of the zone is fail
1 .
Because the system may be in alarm status (except the infrared sensor). When the
alarm sensor (except infrared sensor) is in alarm status, the zone cannot be enabled.
2 .
Wrong installation settings, or the alarm sensor is not connected. If it’s caused by
wrong installation settings, a professional is required.
3 .
Alarm current overload or short circuit.
reset user passworD
If forgot the user password, press pushbutton “#” while in
standby and release it after an extended beep heard .
The password will change to the default 2000 . At the same time,
any alarm messages not sent to Switchboard, will be sent .
With the handset is standby, enter the user p “#”pushbutton. If the wrong password is entered, 3 short beeps will be heard. If the password is correct, the
device will enter the main settings menu and an extended beep will be heard.