![background image](http://html.mh-extra.com/html/bticino/d45/d45_technical-manual_2825385082.webp)
80
VIDEO DOOR ENTRY SYSTEM -
INSTALLATION RULES
D45
Step 5
: Hold the Rj-45 connector
between your fingers with the copper
connectors face up . Slide the wires
into the connector, ensuring that each
coloured wire goes into its matching
slot . Push the connector firmly against
the wires .
Step 6
: Before lock the wires inside the
connector, check from the top of the
connector to see that each wire is tightly
connected to the copper connector .
Step 7
: after the final check, Place the
attached Rj-45 connector into the wire
crimping tool . Squeeze the crimper
handles down to lock the wires in place
inside the connector . When squeezing,
a “click” sound should be heard .
The following picture shows a correctly
fitted connector .
Step 8
: test the cable .
Connect the two Rj45 connectors to the
tester . Turn on the test . The two groups
of lights will be flashing . If the 8 lights
turn to green one by one, it means the
cable is correctly assembled . Any red
lights or yellow lights indicate an open
circuit or bad connection .
Two wire cables must be used in the
following conditions:
1 . System power supply connection to
floor shunt (323002)
2 . Addition power supply connection
to Floor shunt
3 . P18V connection to IT1 P18V
4 . EP/ Backbone/main EP connection
to door lock, EP/ Backbone/main EP
connection to door lock and door
lock connection to power supply
Type DC-loop: 2x1 .0 mm²
Resistance: 39 .4Ω/1km
Rj45 connections