Setting the number of households per floor
FuncTions
operaTion
reMarks
Enter setup submenu for number of
households per floor
While in the initial installation setup status, press and hold the MC pushbutton twice to enter the setup submenu for
the number of households per floor. Note: the first number to set after entering the submenu is the tens position.
The number of households per floor cannot be
less than the household number. the range is
1-99. The default number is 4.
Set the parameter
Press the MC pushbutton to add 1 unit to the relevant position. If the pushbutton is pressed after the input parameter
has reached 10, 3 short beeps will indicate wrong operation and the device will exit the number of households setup
submenu automatically and return to the initial installation setup status.
Select setting item and exit the
submenu
Press the door lock release pushbutton to move to the next setting position, the order is: tens- units-exit current
setting item, back to initial installation setup status. After moving to that position, the parameter of that position will
be 0. Before exiting, please check if the setting parameter is correct. If correct, a long beep will be heard and the set
parameter will be saved. Otherwise, 3 short beeps will be heard and the parameter will not be saved.
Exit
1) Press the door lock release pushbutton to move to the last item. Press the door lock release pushbutton again to exit
the current submenu and return to the initial installation setup status.
2) If the operation is performed wrongly, 3 short beeps will be heard the unit will automatically return to the initial
installation setup status.
Set external
SOS to be NO/NC
FuncTions
operaTion
reMarks
Select the setup submenu for SOS
NO/NC
While in the initial installation setup status, press and hold the MC pushbutton five times to enter the setup submenu
for SOS NO/NC. Read the current parameter. If it’s NO, the parameter is 1 and the message light will be on. If it’s NC, the
parameter is 0 and the message light will be off.
Default: always on
Set the parameter
Press the MC pushbutton to increase the parameter by 1. The parameter will return to 0 after it reaches to 2. When
parameter is 1, SOS is NO type, and the message light is also on. When parameter is 0, SOS is NC type, and message
light is also off. During setup the parameter will be saved automatically.
Exit
1) Press the door lock release pushbutton to exit the current submenu and return to the initial installation setup status.
2) If the operation is performed wrongly, 3 short beeps will be heard the unit will automatically return to the initial
installation setup status.
example:
Once in the initial installation setup status press and hold MC
5 times . If SOS status is the default parameter, the message
light will be on, which means the SOS is NO type . Press the
Switchboard call key once, message light will go off, which
means SOS will be always off . Press the Switchboard call key
once, message light will go on, which means SOS will be NO
type . Other operation may be deducted by analogy . Finally,
press the door lock release pushbutton to exit the initial
installation setup status . Once in the initial installation setup
status press and hold the door lock release pushbutton
to exit the installation setup status and return to standby
status .