107
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
323018 - ep/switchboarD shunt conFiguration
possible conFiguration proceDure
Mode 1
Resistor configuration
√
Keyboard configuration
√
RS232 configuration
√
conFigurator position For ep/
switchboarD shunt
CF1 CF2 CF3 CF4 CF5 CF6
MIN MIN MAX MAX DEV DIR
0
4
0
5
0
0
posiTion Mode 1 value For conFig. reMarks
CF1
MIN
0
x
CF2
MIN
4
x
CF3
MAX
0
x
CF4
MAX
5
x
CF5
DEV
0
x
CF6
DIR
0
x
The 323018 used to extend one Switchboard, Switchboard
address range is 4 to 5; all main EP are installed in the B2 port
of 323018, configuration as follows:
F F I
I #I #I
323009 leD inDications
Directions for the configuration:
Optional configuration alternatives for 323009 .
1/Mode 1 2/Mode 2 Remarks
resisTor conFiguraTion
MeThod
√
√
Not inserting the configurator resistor,
the value will regard as 0.
pushbuTTon on MeThod
√
√
rs232 MeThod
√
√
Remarks . When using item 323009, the room number is
configured automatically, no need to set it at the handset .
Press Mode 1 and Mode 2 to select the desired configuration
method . The user can select any method based on system
complexity and structure . When the phisical configurator is
inserted, you take the priority and RS232 serial interface and
pushbutton configuration ways are disabled (has no effects) .
When altering the configurator resistance, press and hold
down both the S1 key and the S2 key for more than 2 seconds,
until the CFG LED indicator comes one . Release the keys and
restart device item 323009 for the new configuration to take
effect . If the configuration is correct, the CFG indicator will
be off in 20 seconds or it will flash slowly .
Directions for item 323009 configuration: