![background image](http://html.mh-extra.com/html/bticino/d45/d45_technical-manual_2825385038.webp)
SONORA -
CARATTERISTICHE GENERALI
36
VIDEO DOOR ENTRY SYSTEM -
GENERAL FEATURES
D45
323003 - riser shunt
System accessories overview
1 .
Configuration using physical configurators
There are 3 configuration methods using physical
configurators: mode 1, mode 2 and mode 3 . The user can
choose one of them according to the complexity of the
system . The 10th bit is used to mark the mode used . For
the details please see the system configuration chapter .
2 .
Configuration
by
COM
Use an appropriate cable to connect this device to a
PC and enter all the configuration information for this
device using the configuration tool installed on the PC .
3 .
Configuration using the pushbuttons
n
Enter configuration status: in standby press input key S2
and hold for 2 s . The CFG light will be always on . Enter
configuration setup status .
n
Enter the configuration number (i .e . select one
configurator): press S2 to count . Each pressure will
increase the number by one (no press= 1st one) and the
CFG light will flash once .
n
Confirm the configuration number: press S1, the CFG light
flash quickly twice . Then it will come on steady .
n
Enter configuration parameter: press S2, the default
parameter is 0 . Increase by 1 with each pressure . The CFG
light will flash quickly twice . The highest number possible
is 9 .
n
Confirm the configuration parameter: press S1, the CFG
light will flash quickly twice and then flash slowly twice at
the same time . Then the configuration procedure for this
step is now completed .
n
Set next parameters: if necessary, set the other
configuration parameters, press S2 . The CFG light will
flash quickly 3 times . Then proceed according to (2) .
n
Complete the configuration: press S1 to exit configuration .
The CFG light will be off .
n
If the operation is successful, the CFG light will flash slowly
once, and then come on steady . If the configuration is not
successful, the CFG light will be off .
For example: conFigure cF4 as 5
1 . Enter configuration status: in standby press input key S1
and hold for 2 s .
2 . Enter the configuration number: press S2 3 times .
3 . Confirm the configurator number: press S1 .
4 . Enter the configuration parameter: press S2 5 times .
5 . Confirm the configuration parameter: press S1 .
6 . Complete the configuration: press S1 to exit
configuration .
conFiguration enquiry
1 . Enter configuration status: in standby press input key
S1 and hold for 2 s . The CFG light will come on and the
device will switch to configuration enquiry status
2 . Enter the configurator number (i .e . select one
configurator): press S2 to count . Each pressure will
increase the number by one (no press= 1st one) and the
CFG light will flash once .
3 . Confirm the configuration parameter: press S1, the CFG
light will flash quickly a number of times . This number
of times depends on the parameters being read (for
example, if the parameter read is 0, there is no flashing,
for one it will flash once, for two it will flash twice) . Other
operations may be deducted by analogy .
4 . Exit configuration enquiry status: The CFG light will be
off . If no key is pressed for 10 s during the operation the
device will automatically switch to standby . The CFG
light will be off .
5 . If there are 323011 in system or Switchboard be install
in riser then need additional configuration in riser shunt
as listed below :
These configuration only can be set by SF2 configuration
software or by keyboard .
conFiguraTion sloT
Definition
Remark
CF11 CF12
First EP number in this riser
From 1 to 80
CF13 CF14
Riser EP quantity of riser
CF15 CF16
Riser Switchboard number
From 1 to 15