124
VIDEO DOOR ENTRY SYSTEM -
CONFIGURATION
D45
1 .
The indicators flash when the handset is called, but there
is no ring.
When the handset being called does not ring check if it
in silent mode . If yes, please switch it over to standard
common mode .
2 .
The indoor unit is unable to monitor the entrance panel.
Check whether the first entrance panel in the riser has
been set as the no 1 entrance panel, and make sure that
the numbers of the entrance panels in the riser are in
sequence without repetitions .
3 .
Unable to monitor the Small EP.
The function for monitoring the small EP can be only
used after installation personnel has set the system
depending on the actual requirements . If the unit has
been set as a door bell, then the function for monitoring
the gate EP will be disabled automatically .
4 .
Double click to turn Small EP monitoring on.
When starting the small EP monitor function make
sure that the double click interval is kept within 800 ms
(namely quick double click on the monitor key), or it will
be considered a request to monitor the EP .
5 .
How to make sure that the riser installation is correct.
Once installing a handset, first set its number as 101
(default ex-factory value) . The entrance panel will now
call handset 101 . If the call gets through correctly, the
normal video image will appears, confirming that the
hardware installation and line connection are correct
(on adjusting other handset, first disconnect the first
handset at the 1st floor to avoid having two handsets
with the same address) . In case of more problems, please
check the configuration of other related devices . Once
the settings have been confirmed, it is possible to set the
handset with its actual number .
6 .
When the entry panel calls a handset with a certain
number, the handset answers but there is no voice or
video signal.
If the entrance panel can call all handsets with a number
smaller than a certain number (e .g . all handset with
number lower than 501 can be called), these handset will
answer normally . However if a call is made to a handset
with that number or a higher number, there is no sound
on answering and no video image is displayed . Now
confirm whether the configuration on the riser shunt
is correct . Take out the riser shunt from the unit system
and directly connect the EP to the floor shunt to check if
it works correctly . If it does it means that the riser shunt
is set incorrectly .
7 .
The entrance panel fails to call a certain handset.
The handset number may be set incorrectly, in which
case reset the number and try again . If the call still fails,
Troubleshooting
set the number as 101 and try again . If it is successful it
may be that the handset household on each floor is not
the same as the #II setting on the entrance panel . Reset
this again . If the call still fails, it may be due to the line or
other devices . Replace the handset and check the line .
The handset will not answer calls while in installation
setup status . Exit installation setup status and try again .
8 .
The entrance panel can call the handset normally
without any problems.
However, the internal indoor units can’t be called through
and when answered, they can’t have a talk.
Please make sure that the set parameters of two indoor
units are identical . if unable to ensure that, please restore
the default parameters and reset .
9 .
The Small EP can’t have a conversation with the handset
and there is no video signal
Please disable the doorbell function (this function is
disabled by default) . When the doorbell function is
enabled, and the small EP or the doorbell calls in, the
system will ring but no conversation will be possible .
This is normal and ringing will automatically stop after
10 seconds .
10 .
On connecting the Apartment interface, the handset’s
own number won’t be the same as the one previously
set.
On connecting an apartment interface, the handset will
automatically detect the connection and change its own
number to 101 . The handset will automatically use the
number set by the apartment interface .
11 .
On being powered, the handset will send the
SOS to the Switchboard.
SOS switch type is different from the setting type .
Default setting SOS type is NO (Normally Open) .
12 .
The alarm handset cannot be armed.
If the alarm handset cannot be armed, it may be due to
the following:
n
the probe type is incorrectly set . For example, the normally
closed type is set as normally open;
n
the probe is not connected or not correctly set . First
ensure that the probe is correctly connected to
hardware, and then open software setup to enable it .
There is an overcurrent on the alarm probe and it cannot
be guarded until repowered after 10 seconds .
13 .
The handset is unable to start the Small EP monitoring
function.
n
IU be set as Slave
Only the master handset can monitor the Small EP .
n
IU enable door bell function
If the handset starts the doorbell function, it will
automatically close down the small EP .