323016 - villa shunt
Villa shunt is installed in the public low voltage box in villas
areas . The handset of each villa’s resident can connect all
the signal lines to the bus through the Floor shunt and the
Villa shunt . One 323016 can be connected to 4 Floor shunt . If
323002 is connected to 323016, it can only be linked to one
house, and only one to three handsets . Device item 323016
can distribute the video signal, audio signal, data signal of
the bus to the connected Floor shunt, so that the signals
from the unit bus to the Floor shunt can reach a maximum
distance of 200 meters, meeting the special requirements of
villas .
Directions to the setting of the video-gain switch (up being
ON and down being OFF)
Note: users can turn the switch at any line lenght and directly verify the
setting effect. For details on how to adjust the B/W image,refer to floor shunt
specifications.
Villa shunt
1 2
POWER
+
-
1
2
3
4
4
1 2
on
oFF
Video gain setting instruction (switch up ON, switch down
OFF)
b/w signal
Distance
1
2
200 m
OFF
OFF
200 - 400 m
ON
OFF
OFF
ON
400 - 500 m
ON
ON
System accessories overview
legenD
1 . DC30V;
2 . Auxiliary power connectors: DC30V is the unit system bus
input interface, to connect the Riser shunt SUB SYSTEM
interface or the SUB SYSTEM OUT interface of the last
Floor shunt;
3 . Unit system bus output interface, to connect SUB SYSTEM
IN interface of the next floor shunt, or nothing;
4 . Connects to 4 floor shunts respectively .