![background image](http://html.mh-extra.com/html/bticino/d45/d45_technical-manual_2825385069.webp)
67
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
Each pushbutton-configuration place must be relevant to
the place at the configurator . For example, if the pushbutton
configuration place is coded at 5, then it’s relevant to
DEV (CF5) in the configurator . Configuration methods by
pushbuttons
n
Enter the configuration status: In standby, press the S2
key and hold for 2 seconds . The CFG indicator will flash
for two seconds and switch to configuration status (If
the configurator fitted with a resistor or pushbutton
configuration has been performed incorrectly, the unit
cannot enter configuration status) .
n
Enter the configuration place code (to select a certain
place at the configurator): press the S2 key to reach
the desired number . At every pressure the code will be
increased by one 1 (no pressure will give 1) and the CFG
indicator will flash once .
n
Confirm the configuration place code: Press the S1 key
and the CFG indicator will flash quickly twice . Then it emit
an extended flash to and enter value configuration mode .
n
Enter the configuration place value: Press the S2 key
(defaulted at 0) . Press once and the value will be increased
by 1, the CFG indicator flashing quickly twice .
n
Confirm the configuration place value: Press the S1 key
and the CFG indicator will flash quickly twice; When it
flashes slowly twice, the value is set .
n
Set the next place: If you need to set the value of other
configuration places, press S2 and the CFG indicator will
flash quickly twice . Then continue from point (2) .
n
End the configuration: Press the S1 key to exit
configuration mode . If the procedure has been successful
the CFG will flash once and then come on steady .
The new configuration is now available . If the procedure
fails (one configuration place is over the effective value,
like DEV>1), the CFG indicator will be off and the old
configuration will be kept . If the configuration value
is logically wrong (such as Min>Max), then on reset
the CFG indicator will flash slowly, indicating wrong
configuration and pushbutton operation will stop .
In this case connect the non-zero (1 to 9) resistor to
the configurator and repower to clear all the values
configured using the pushbuttons . Remove the resistor,
repower and reset following the above steps . If during the
operation no pushbutton is pressed for 10 seconds, the
unit will automatically exit the configuration status and
the CFG indicator will go off .
Configuration enquiry methods
n
Enter enquiry status: In standby, press the S1 key for 2
seconds and the CFG indicator will flash slowly and enter
configuration enquiry mode (This status is not accessible
in case of wrong configuration) .
n
Enter the configuration code (to select a certain place
at the configurator): press the S2 key to increase the
numbers . At every pressure the code will be increased by
one 1 (no pressure will give 1) and the CFG indicator will
flash slowly twice .
n
Read the configuration value: Press the S1 key and the
CFG indicator will flash . The number of times it will flash
will depend on the size of the value (For example, if the
reading result is 0, it won’t flash; if it’s 1, it will flash once,
and if 2, it will flash twice, and so on), and then move to
the next step .
n
With the CFG indicator off, it will exit configuration
enquiry status: If during the operation no pushbutton is
pressed for 10 seconds, the unit will automatically exit the
status .