SONORA -
CARATTERISTICHE GENERALI
8
VIDEO DOOR ENTRY SYSTEM -
GENERAL FEATURES
D45
322010 Digital ep set the Functions
Press the # key for about 5 seconds . Input the master
password as per the prompt on the display and press the #
key for confirmation . When you get to the setting status, you
can enter the following settings as per the prompt: (Press on
the 0 key to scroll through the pages) .
1 . Select 1 and change the master password . The default
master password is 200000 . If you want to change it,
you can input your desired password as per the prompt
and press the # key for confirmation . If two inputs are
identical, then the master password is successfully
changed . If not, it will indicate an error and ask you to
re-enter it . Note that only the administrator is entitled to
keep or modify the master password .
2 . Select 2 to set the signal types to open/close electric
door locks . As per the interface prompt, we can press the
0 or 1 key to set as either often-closed or often-opened
type .
3 . Select 3 to complete the setting of the anti-removal
alarm .
This function must be used together with the anti-removal
alarm pushbutton . By selecting this function and pressing the
anti-removal alarm button the entrance panel automatically
send a removal alarm . If a wrong alarm is sent due to A
wrong settings during installation, switch the power off and
press the alarm button . Then switch the power on again
to cancel the alarm settings . When the entrance panel has
been installed, reopen the anti-removal alarm function .
4 . Select 4 to complete the mode setting of the room
number .
Eight options are available for your selections . When using
the entrance panel as the (Riser EP or secondary EP), the first
and the second mode can be selected . When using it as the
(Backbone EP or main EP), the 3rd, 4th 5th, 6th, 7th and 8th
mode can be selected, depending on the actual situations .
The default factory setting is the 1st mode .
Entrance panel functions overview
When used as (Backbone EP or main EP):
Mode 3 and Mode 4:
these are commonly used modes .
When the riser number (building number and unit number)
plus floor number plus room number is not above 8 digits,
one of them can be selected . Now the riser number actually
includes the building number . Take Unit 1 of Building 1 for
example, the riser number will be 0101 .
Mode 1: 8888
88 Floor number
88 room number
Mode 2: 88A
88 Floor number
A room number
Mode 1: 8888
Mode 2: 88A
RISER MoDE
F
F
r
r
Mode 3: 8888-88 88
Mode 4: 8888-88A
BAckBoNE EP oR MAIN EP
F
u
u
F
r
r
Mode 3: 8888-8888
8888 unit number
88 Floor number
88 room number
Mode 4: 8888-88A
8888 unit number
88 Floor number
A
room number
Mode 5: 888-88-8888
888 building number
88
unit number
88 Floor number
88 room number
Mode 6: 888-88-88A
888 building number
88
unit number
88 Floor number
A
room number
Mode 5 and Mode 6
: When the building number plus unit
number (building number and unit number are coded
separately) plus floor number plus room number is not
above 9 digits, one of them can be selected . Take Room
1 5th floor, Unit 2 of Building 101 for example, the riser
number will be 101-02-0501 .
Mode 5: 8888-8888
Mode 6: 8888-88A
BAckBoNE EP oR MAIN EP
F
F
u
u
b
b
r
r