Electric Drives
and Controls
6–3
Bosch Rexroth AG
Servodyn-D
1070 066 032 / 03
Replacing components
6.2
Drive modules
CAUTION
Destruction of power units!
Note the tightening torque of 3 Nm for the power connections U,
V, W.
6.2.1
VM...K and DM...K
The DC link connection is achieved with conductor bars ”C” and ”D” at
the front side of the modules:
1. Release fastening screw below the cover, unhinge and remove
cover upward.
2. Release screws of the pre-assembled conductor bars, push bars be-
low the fastening screws of the adjoining left module, and tighten
screws again.
C
D
CAUTION
Destruction of power units!
Please note the tightening torque of 3 Nm for the screwed DC link
connections.
3. Reinstate all covers.
DANGEROUS ELECTRICAL VOLTAGE
Busbars carry lethal voltages during operation.
It is absolutely necessary to install the shock-protection covers at
both ends of each row of modules.
Содержание Rexroth Servodyn-D Series
Страница 23: ...3 4 Electric Drives and Controls Bosch Rexroth AG Servodyn D 1070 066 032 03 Marks certifications Notes ...
Страница 65: ...5 10 Electric Drives and Controls Bosch Rexroth AG Servodyn D 1070 066 032 03 Connection overview Notes ...
Страница 71: ...6 6 Electric Drives and Controls Bosch Rexroth AG Servodyn D 1070 066 032 03 Replacing components Notes ...