Electric Drives
and Controls
4–17
Bosch Rexroth AG
Servodyn-D
1070 066 032 / 03
VMA..KR, VMA..B,C,D,F and DM/DS error displays
F code
display
Meaning
Error
number
F70
0
Measuring system initialization error – Without detailed fault documentation
1
Defective motor rating plate; faulty data transfer
2
Missing interface –> Defective cable, loose connection, defective rating plate
3
Defective motor rating plate
4
Motor rating plate without parameters
5
Faulty data transfer; Defective memory location in motor rating plate
6
Defective encoder; Faults upon absolute-value data transfer
7
Defective encoder; Faulty data transfer (absolute-value parity check)
8
Missing hardware trigger on pin NP_2 (zero-marker-storage-error)
9
Missing interface; Defective cable; Loose connection; Defective rating plate
11
Missing interface; Defective cable; Loose connection; Defective rating plate
12
Missing interface; Defective cable; Loose connection; Defective rating plate
13
Missing interface; Defective cable; Loose connection; Defective rating plate
14
Missing interface; Defective cable; Loose connection; Defective rating plate
15
Missing interface; Defective cable; Loose connection; Defective rating plate
16
Missing interface –> Software error
84
Defective motor rating plate
85
Defective motor rating plate
86
Faulty data transfer; Defective motor rating plate
87
Faulty data transfer; Defective motor rating plate
88
Faulty data transfer; Defective motor rating plate
89
Faulty data transfer; Defective motor rating plate
90
Faulty data transfer; Defective motor rating plate
91
Faulty data transfer; Defective motor rating plate
92
Faulty data transfer; Defective motor rating plate
93
Faulty data transfer; Defective motor rating plate
94
Faulty data transfer; Defective memory location in motor rating plate
95
Motor rating plate without parameters
96
Missing interface; Defective cable;Loose connection;Defective motor rating plate
97
Missing interface; Defective cable;Loose connection;Defective motor rating plate
98
Faulty data transfer; Defective motor rating plate
99
Faulty data transfer (CRC check, motor rating plate)
100
Faulty data transfer; Defective motor rating plate
101
Faulty data transfer (CRC check, motor rating plate)
102
Motor rating plate without parameters
103
Faulty data transfer; Defective memory location in motor rating plate
104
Faulty data transfer; Defective memory location in motor rating plate
105
Faulty data transfer (CRC check, motor rating plate)
106
Defective encoder –> Signal amplitude too low; Missing illumination ....