4–12
Electric Drives
and Controls
Bosch Rexroth AG
Servodyn-D 1070 066 032 / 03
VMA..KR, VMA..B,C,D,F and DM/DS error displays
Displays flash
alternately.
Action
Error
The drive has switched off.
Assignment mains connection mod-
ule – VM
Mains connection module and supply mod-
ule do not have the same power output
stage.
D
Combine compatible modules
CAN bus only:
Internal command active
The controller must not enable the drive at
this time.
Runtime Personality Module
D
Check stable position of personality
module
D
Replace personality module
Runtime I
2
C-Bus
D
Replace module
Stacking error
D
Replace module
Inadmissible memory access
D
Replace module
Synchronization error I controller
Internal synchronization of the VM firm-
ware disturbed
D
Replace module
Speed controller plausibility error
.
For details of the fault, refer to
S-0-0095, cf. page 4–14.
D
Check motor cable
D
Switch modules off because of
danger-
ous
electrical voltage!
Check DC link connection,
check DC link voltage
D
Motor stalled
D
Turn off torque reduction
D
For more details, refer to P-0-0010
VM error
Torque is immediately turned off because
of an operating fault (e.g. under-/overvol-
tage)
D
Check error message on VM
D
Clear error by “Reset Diagnostics class
1 error”
.
Check whether the fan on the bot-
tom side of the module has failed.